5.4 - Drive Ratio/Shaft Alarms (where fitted)
Warns the operator of breakdown, slippage or incorrect sprockets between the controlled drive
and the final metering mechanism. Drive ratio alarms are available for all four bins.
Once enabled and set, all drive ratios are monitored continuously and will alarm if the ratio is
±10% outside of the set ratio.
Drive ratio alarms must be enabled before setting.
5.4.1 Enable
1. While in the “ALARM POINT” menu (displaying air and fan) press the “NEXT” softkey to display
drive ratio alarm points.
2. Press and hold for 3 seconds the softkey pointing at each drive ratio alarm to be enabled.
3. “DISABLED” will change to “ENABLED”. If a bin is metering product the live drive ratio will be
displayed. See below.