Linear Actuator Over Variable Gearbox
1. Check ”PRODUCT CALIBRATION” screen is displayed. See below.
2. Press bottom “READY” softkey.
3. Press green button on the pod to move the gearbox actuator in one direction. Release and
press the green button again to move the gearbox actuator in the opposite direction.
4. Adjust the gearbox actuator to an approximate normal working position on the calibration dial
for the intended rate as suggested by the airseeder manufacturer.
5. Be ready to catch the product test batch from the metering system.
6. Disengage clutch. Turn the metering system manually to deliver a sizeable calibration sample as
recommended by the airseeder manufacturer. Accurately weigh the product.
7. Press the softkey pointing at “TEST WEIGHT”. Use the arrow keys to enter the weighed
amount.
8. Press the bottom “UPDATE” softkey. The “PULSE/KG” factor for that product will be
automatically calculated.