Liquid
Liquid control is available on all four bins. On a Simplicity liquid bin it is set up on bin 4 however the
3500 software will allow it to work on four bins.
Note: Prior to selecting liquid, if a master valve is being used with the liquid then this
must be selected. See OUTPUT 5 & 6.
1. Check “BIN # LIQUID” is displayed. See below.
2. Select Control Type CTRL to “BYPASS” see “Bypass and Direct Control Explained”.
3. Select Control Valve Hold Status HOLD to “STOP” see Bypass and Direct Control Explained”.
4. Press the bottom “START” softkey.
5. Press the green button on the pod.
6. The control valve (and Master On/Off Valve if fitted) will open then close again after five
seconds.
7. Press the “END” softkey. A “MAX” pulses per minute factor will be returned.
8. Repeat steps 4 & 5, if the system was not primed initially.
9. For liquid control, initially set the SPD and STEP values to 60 and 1 respectively.
10. Press “BACK” softkey. Check “SETUP OK” is displayed under the drive to confirm it has been
set up correctly.
NOTE: 3500 will return MAX PPM. MAX PPM = P/Lt (of flow meter) x Lt/Min (flow rate).
(Max of 10000PPM for 3500 = higher results will require a signal divider).