2.2.1 - Enable Bin Drive
1. Press “CAL” key, calibration menu appears.
2. Highlight “SETUP” and press “CAL”. The “CONTROL SETUP MENU” appears.
BIN 1
BIN 2
BIN 3
BIN 4
<PREV NEXT> SELECT RATES BACK EXIT
ENABLED
DISABLED
DISABLED
DISABLED
CONTROL SETUP MENU POD
Press & hold for
3 seconds to
enable Bin 1
3. Press and hold the softkey pointing at the required bin for 3 seconds.
4. Bin will change from “DISABLED” to “ENABLED”.
Linear Actuator over Gearbox
No setup screen is displayed. The gearbox drive is immediately calibrated upon selection.
Output 5 & 6
These two outputs are only selected if “LIQUID” is being used. Output 5 & 6 have the ability to run
two wire and three wire master on/off valves for liquid only. They must be associated with bin 1, 2,
3 or 4. There can only be one master on/off valve per bin.
On a Simplicity Liquid setup OUTPUT 5 must be enabled as a 2 WIRE VALVE and associated to BIN
4.
This is shown below –