Step 2
2 - Drive Setup
Drives for each bin must be selected and calibrated (setup) before operation.
2.1 – Drives Available
Bins 1, 2 & 3 Bin 4 Output 5 & 6 Description
DC MOTOR DC MOTOR 12 volt DC motor
GEAR BOX GEAR BOX Linear actuator over gear box (ground
drive)
HYD PROP 2 HYD PROP 2 Hydraulic proportional valve with
dither
HYD PROP/XPRO
HYD PROP/XPRO
Hydraulic proportional valve
HYD MFC HYD MFC Motorized flow control valve
HYD DANFOSS HYD DANFOSS Hydraulic PVG32 Danfoss valve
(proportional valve)
HYD DANFOSS L
HYD DANFOSS L Hydraulic PVG32 Danfoss valve
(proportional valve) operating a pump
LIQUID LIQUID Control valve and flow sensor
MONITOR MONITOR Solenoid activated clutch for bin –
monitors only – no control.
CLUTCHSOL CLUTCHSOL Solenoid activated clutch on ‘run/hold’
CLUTCHLIN Linear actuated clutch on ‘run/hold’
Section Valve 2 wire Motorised 2 wire section valves
Section Valve 3 wire Motorised 3 wire or solenoid section
valves
Note
An extra control option is available for bin 4: “CLUTCHLIN” (linear actuator clutch).
2.2 – Setting Up Drives
To calibrate a bin drive, the bin must be enabled and a drive selected. Follow the procedures below
“2.2.1 - Enable Bin Drive” and “2.2.2 - Select Bin Drive” for each bin.