Technical information

2-16
Table 2.3.5: Average complex modulus test results for Mix 3 (Barde and Cardone,
2004).
Test Temperature
ºC (ºF)
Test Frequency
[Hz]
Dynamic Modulus
MPa (ksi)
Phase Angle
[degrees]
-10.0
(+14)
25 22,559 (3,272) 4.9
10 21,386 (3,102) 7.8
5 20,300 (2,944) 8.9
1 17,801 (2,582) 10.5
0.5 16,667 (2,417) 11.3
0.1 13,991 (2,029) 13.5
+4.4
(+40)
25 11,884 (1,724) 11.2
10 10,786 (1,564) 13.1
5 9,879 (1,433) 15.6
1 7,858 (1,140) 17.6
0.5 7,111 (1,031) 18.9
0.1 5,457 (791) 21.8
+21.1
(+70)
25 7,113 (1,032) 16.7
10 5,928 (860) 19.1
5 5,087 (738) 21.9
1 3,504 (508) 27.3
0.5 2,970 (431) 28.0
0.1 1,992 (289) 30.1
+37.8
(+100)
25 2,634 (382) 24.3
10 2,038 (296) 20.5
5 1,624 (236) 23.7
1 1,008 (146) 28.7
0.5 851 (123) 28.6
0.1 604 (88) 27.9
+54.4
(+130)
25 673 (98) 31.2
10 534 (77) 28.9
5 448 (65) 29.7
1 313 (45) 26.5
0.5 276 (40) 25.4
0.1 216 (31) 24.1