Technical information
2-15
Table 2.3.4: Average complex modulus test results for Mix 2 (Barde and Cardone,
2004).
Test Temperature
ºC (ºF)
Test Frequency
[Hz]
Dynamic Modulus
MPa (ksi)
Phase Angle
[degrees]
-10.0
(+14)
25 25,440 (3,690) 6.6
10 24,150 (3,503) 9.7
5 22,781 (3,304) 10.5
1 20,048 (2,908) 12.1
0.5 18,791 (2,725) 12.8
0.1 15,703 (2,278) 15.1
+4.4
(+40)
25 16,581 (2,405) 10.9
10 14,813 (2,148) 12.2
5 13,710 (1,988) 13.9
1 11,191 (1,623) 16.0
0.5 10,168 (1,475) 17.2
0.1 7,951 (1,153) 20.4
+21.1
(+70)
25 8,575 (1,244) 15.3
10 7,321 (1,062) 15.3
5 6,302 (914) 22.6
1 4,503 (653) 25.0
0.5 3,898 (565) 26.1
0.1 2,722 (395) 28.6
+37.8
(+100)
25 4,238 (615) 26.2
10 3,498 (507) 27.3
5 2,792 (405) 24.9
1 1,752 (254) 32.5
0.5 1,481 (215) 32.1
0.1 1,044 (151) 31.2
+54.4
(+130)
25 1,504 (218) 26.2
10 1,200 (174) 22.7
5 985 (143) 21.5
1 655 (95) 25.4
0.5 578 (84) 26.4
0.1 450 (65) 27.4