Technical information

2-14
Table 2.3.3: Average complex modulus test results for Mix 1 (Barde and Cardone,
2004).
Test Temperature
ºC (ºF)
Test Frequency
[Hz]
Dynamic Modulus
MPa (ksi)
Phase Angle
[degrees]
-10.0
(+14)
25 23,057 (3,344) 6.1
10 21,808 (3,163) 9.2
5 20,585 (2,986) 9.7
1 18,129 (2,629) 10.9
0.5 17,017 (2,468) 11.5
0.1 14,364 (2,083) 13.2
+4.4
(+40)
25 13,792 (2,000) 10.1
10 12,365 (1,793) 11.2
5 11,418 (1,656) 13.6
1 9,391 (1,362) 15.3
0.5 8,563 (1,242) 16.3
0.1 6,722 (975) 18.9
+21.1
(+70)
25 7,099 (1,030) 16.0
10 5,983 (868) 17.0
5 5,052 (733) 23.1
1 3,529 (512) 26.5
0.5 3,009 (436) 27.4
0.1 2,061 (299) 29.3
+37.8
(+100)
25 2,622 (380) 27.5
10 2,139 (310) 23.5
5 1,694 (246) 25.3
1 1,020 (148) 33.6
0.5 862 (125) 32.3
0.1 589 (85) 30.2
+54.4
(+130)
25 1,054 (153) 22.2
10 855 (124) 15.1
5 685 (99) 16.6
1 436 (63) 21.1
0.5 382 (55) 22.8
0.1 286 (41) 26.9