Technical information

4-16
Table 4.3.1: Combined complex modulus properties for APT n1 / NCAT N1 (based on
equations 4.3.1 to 4.3.4).
Test Temperature
ºC (ºF)
Test Frequency
[Hz]
Dynamic Modulus
MPa (ksi)
Phase Angle
[degrees]
-10.0
(+14)
25 24,951 (3619) 6.5
10 23,669 (3433) 9.6
5 22,329 (3239) 10.3
1 19,653 (2850) 11.8
0.5 18,426 (2672) 12.5
0.1 15,427 (2237) 14.7
+4.4
(+40)
25 15,995 (2320) 10.7
10 14,299 (2074) 12.0
5 13,229 (1919) 13.9
1 10,814 (1568) 15.9
0.5 9,832 (1426) 17.0
0.1 7,693 (1116) 20.1
+21.1
(+70)
25 8,265 (1199) 15.4
10 7,038 (1021) 15.6
5 6,037 (876) 22.7
1 4,295 (623) 25.2
0.5 3,708 (538) 26.3
0.1 2,580 (374) 28.7
+37.8
(+100)
25 3,873 (562) 26.4
10 3,188 (462) 26.6
5 2,543 (369) 25.0
1 1,584 (230) 32.7
0.5 1,339 (194) 32.1
0.1 939 (136) 31.0
+54.4
(+130)
25 1,405 (204) 25.4
10 1,122 (163) 21.2
5 918 (133) 20.6
1 606 (88) 24.6
0.5 534 (77) 25.8
0.1 413 (60) 27.3