Specifications
Section U
Servo Calibration
U.1 Servo Calibration
When S100 is in the Calibrate Position Adjust the Tune and Load
servos for a Power Peak and the amount of current for the # of
Modules ON.
When this is achieved, Adjust the following:
TUNE SECTION
POTS MEASURE MEASURE FREQUENCY
R44,R57 U31 PIN 6 = U31 PIN 5 FREQ 1
R48,R52 U31 PIN 7 = U31 PIN 5 FREQ 2
R27,R56 U31 PIN 8 = U31 PIN 5 FREQ 3
LOAD SECTION
POTS MEASURE MEASURE FREQUENCY
R26,R50 U31 PIN 10 = U31 PIN 13 FREQ 1
R46,R55 U31 PIN 11 = U31 PIN 13 FREQ 2
R25,R54 U31 PIN 12 = U31 PIN 13 FREQ 3
888-2339-002 U-1
WARNING: Disconnect primary power prior to servicing.