Specifications
Figure 3-6
DRIVER MULTIMETER
POSITION FUNCTION
PROBE PK AC Probe will measure peak AC voltages 0 to 30 Vac
PROBE +VDC Probe will measure positive direct current voltages 0 to +3 Vdc
PROBE +VDC Probe will measure positive direct current voltages 0 to +30 Vdc
PROBE -VDC Probe will measure negative direct currrent voltages 0 to -30 Vdc
PREDRIVER IDC Measures Predriver current 0 to +10 A
PREDRIVER +VDC Measures Predriver voltage 0 to +300 Vdc
CONTROL +VDC Measures Driver Supply Regulator reference voltage 0 to 100
Vdc
DRIVER +VDC Measures Driver Supply voltage 0 to 300 Vdc
DRIVER IDC Measures Driver Supply current 0 to +100 A
DRIVER 14A +VDC Measures Driver D14 “A” supply voltage 0 to +300 Vdc
DRIVER 14B +VDC Measures Driver D14 “B” supply voltage 0 to +300 Vdc
Table 3-6
888-2339-002 3A-11
WARNING: Disconnect primary power prior to servicing.