WARNING: Disconnect primary power prior to servicing.
DAX-1/DAX-3
Section 5 Maintenance and Alignments
STEP 16 On the VT100 page 5, press ā€œIā€ and lower the Reflected Power Trip to
70W per PA using the down arrow key (see Table 5-4 below)
STEP 17 Still on the VT100 page 5, press "4" and increase the Reflected Power
Null, using the up arrow, until the Reflected Power Cal. reading
indicates lowest value possible
STEP 18 Raise the transmitter power to nameplate output power. Verify the
transmitter DC Current metering is approximately 3.8A per PA with no
modulation, as reported on the GUI metering screen (see Table 5-5
below).
5.5.2.3 Reset Power Levels:
This last portion of this procedure re-establishes the desired power levels using the
newly calibrated metering:
STEP 19 Go to the POWER screen on the transmitter GUI
STEP 20 Select Power Level 1 (see "3.3.3.2 Selecting Power Levels 1 - 5" on page
3-5 for details)
STEP 21 RAISE or LOWER the power to match the Power Level Range setting
(small numeric value at lower right side of display) for that Power Level
Table 5-4 STEP 16 Power Settings
Model Watts
DAX-1/1R 70
DAX-3 210
DAX-5 350
DAX-6 420
Table 5-5 STEP 18 DC Current Settings
Model Watts DC Amps
DAX-1/1R 1000 3.8
DAX-3 3000 11.4
DAX-5 5000 19.0
DAX-6 6000 22.8