Specifications

5/2/2013 888-2500-001 5-5
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
DAX-1/DAX-3
5.3.3 Power Limit Setup
The DAX transmitter can be remotely forced to a predetermined power level via the
Remote Power Limit Select I/O line, J7-8 on the External I/O board. To set that value
use the following procedures.
5.3.3.1 Via Front Panel GUI
STEP 1 Press the INFO button to navigate to the submenu screen
STEP 2 Select SETUP SUBMENU using the UP or DOWN buttons
STEP 3 Press ENTER to bring up below screen
Figure 5-2 Setup Screen
NOTE: DAX-1R (Redundant PA option) Screen Shown
STEP 4 Scroll to POWER LIMIT and press ENTER
STEP 5 Adjust the level, in Watts, to the desired value using the UP or DOWN
buttons
STEP 6 Press ENTER to store that value
5.3.3.2 Via VT100
See "5.5.1 VT100 Calibrations and Alignments" on page 5-8 below, particularly the
note for accessing the page 4 VT100 configuration screen for the following procedure.
STEP 1 Initiate VT100 programming and navigate to page 4
STEP 2 Type the letter "u" for Remote Power Limit
STEP 3 Use the keyboard’s up/down arrows to adjust the value in Watts to the
level required
STEP 4 Press "Enter" key to store value