Specifications
5/2/2013 888-2500-001 3-13
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
DAX-1/DAX-3
STEP 3 Press the "Enter" key to store that entry
•EXAMPLE: To change the Forward Power Range of Power Level 4 to
2800W; on page 2 of the VT100 screens, type "4", then use your key-
board’s up or down arrow keys to reach 2800. Then hit "Enter" on your
keyboard to store.
To toggle (turn on/off) a command:
STEP 1 Type the corresponding number or letter in parenthesis - do NOT hit
"Enter"
•EXAMPLE: To mute the DAX; on page 2 of the VT100 screens, type
the letter "e". Type "e" again to unmute the transmitter.
STEP 2 Type the same number or letter again to toggle that command
3.5.2 VT100 - Page 1
Figure 3-12
VT100 Page 1 View
3.5.2.1 SYSTEM
Forward Power: Transmitter output power measured using an RF detector on the
Output Monitor board. Forward power is limited to 115% of rated power.