Specifications
5/2/2013 888-2500-001 3-7
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
DAX-1/DAX-3
STEP 12 After the desired power value has been attained using one of these
buttons, press and hold ENTER for >3 seconds (wait for reverse video to
flash, indicating value is saved) to store the setting for that Power Level
STEP 13 Repeat steps 10 - 12 for the remaining desired power levels
NOTE:
For optimum performance it is best to program the desired power level range, as
shown above. Then to make small temporary power level changes, use the
RAISE or LOWER buttons (as long as ENTER is not pressed and held at this
time, this level will only be temporary - once another power level is selected this
power level will revert to its stored preset value).
3.3.3.4 Metering
Pressing METER takes you to a level of menus designed to quickly determine common
operating variables.
NOTE:
All meter readings are +/- 5%.
• FWD PWR: Forward power in Watts
• RFLD PWR: Reflected power in Watts
• VSWR: Current voltage standing wave ratio (Example: 1.17 indicates a 1.17:1
VSWR ratio)
• DC VOLT: B+ voltage
• DC CURR: B+ current in Amps
• +12V, -12V: 12 volt power supplies voltage
• +48V: +48 volt power supply voltage
To view these screens (sample shown below) simply press METER:
Figure 3-7 Sample of METER Status
3.3.3.5 Status Screens via INFO Button
For less routine information, a set of "Status" menus is available via the INFO menu.