Specifications

5/2/2013 888-2500-001 3-5
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
DAX-1/DAX-3
3.3.3.2 Selecting Power Levels 1 - 5
DAX transmitters will be preset at the factory to the customer specified Power Levels 1
- 5. If the power levels have not been specified, the factory defaults are:
To change to a different pre-set Power Level, follow these steps:
STEP 1 Starting from the Main screen, press the POWER menu button to
highlight the PWR LEVEL number on the bottom line of GUI
Figure 3-4 Power Level Highlighted View
STEP 2 Using the UP and DOWN buttons select your choice of Power Level 1
through Power Level 5 (note level range ’preview’ in small numbers to
the right)
STEP 3 Once selected, hit ENTER to make that power level active
3.3.3.3 To Set Desired RF Power Output Level
Once the exact desired power levels for your station have been determined, use the
following procedure to configure as many of the 5 available presets as needed.
Power Level Range settings are where the DAX transmitter is programmed to run in a
preferred range that optimizes the performance and minimizes the distortion through
software and hardware alignment of power supply system and RF power output. After
the ’Range’ is set, the actual RF power output may need to be adjusted to match your
requirements.
Table 3-1 Default Power Levels
Power Level DAX-1/1R DAX-3 DAX-5 DAX-6
1 200W 500W 1000W 1000W
2 400W 1000W 2000W 2000W
3 600W 1500W 3000W 3000W
4 800W 2000W 4000W 5000W
5 1000W 3000W 5000W 6000W