Specifications

2-26 888-2500-001 5/2/13
WARNING: Disconnect primary power prior to servicing.
DAX-1/DAX-3
Section 2 Installation
NOTE:
The Remote Statuses are referenced to the transmitter ground. It is recommended
to connect all Status signal returns to a GND connection. The maximum allowed
voltage on the remote status lines is 30V, the minimum is -2V. The remote status
lines can sink 100mA. All status lines are steady-state active low (sinking current
when active).
NOTE:
The Analog Statuses are linearly scaled DC voltage representations of their cor-
responding signals.
J9-3 Remote Disable STAT Low State Remote Control disabled when active
J9-2 Digital Mode STAT Low State Digital Mode enabled when active
J7-5 GND - Status return
J7-1 GND - Status return
J9-12 GND - Status return
J9-7 GND - Status return
J9-1 GND - Status return
Table 2-6 Analog Status Outputs and Functions
J(n) STATUS NAME ACTIVE FUNCTION
J12-11 EXT FWD
Power Sample
Analog Range
= 0 - 4Vdc
Rated Nameplate Power = 3.0Vdc
J12-9 EXT DC
Current Sample
Analog Range
= 0 - 4Vdc
45A = 3.0Vdc
J12-8 EXT DC
Voltage Sample
Analog Range
= 0 - 4Vdc
260Vrms = 3.0Vdc
J12-6 +5Vdc Supply - +5V current-limited source (relative to
GND) for external purposes
Table 2-5 Remote Status Outputs and Functions
J(n) STATUS NAME ACTIVE FUNCTION