Specifications

2-16 888-2500-001 5/2/13
WARNING: Disconnect primary power prior to servicing.
DAX-1/DAX-3
Section 2 Installation
2.3.5 RF Connections
NOTE:
Place a piece of cardboard over exhaust holes in top of cabinet when working
with small hardware that could fall through during installation.
Carefully connect the output transmission line from the antenna to the 7/8 EIA flange
connector for the DAX-3, or N-connector for the DAX-1 located on the top rear of
the cabinet.
2.3.6 Transmitter I/O Wiring
The entrance for I/O cabling is a circular opening, located on the front-right top (as
viewed from the front of DAX) of the cabinet. This entry provides a direct path towards
the remote terminals on the External I/O board. See Figure 2-7 on page 2-19 for a view
of the connections on the right side of this board.
For additional wiring required for any extra equipment that may be mounted in the
upper cavity there are two more openings just to the left (as viewed from the front of
DAX) of the exhaust holes near the rear on the DAX transmitters top. These may be
used as desired for other installation needs.
2.3.6.1 WAGO Connector Operation
The DAX transmitter utilizes the WAGO 733-series connectors for remote terminal
connections. Follow the procedure below to facilitate a quick and secure hook up for
your I/O signal cables.
STEP 1 Prepare cables by removing 1/4" of jacket
STEP 2 Twist exposed wire ends
NOTE:
Do not solder these wire ends. The WAGO connector works best with unsoldered
strand-type wire.
STEP 3 Locate the supplied tool, or a narrow insertion tool (small jewelers
screwdriver) and the included female connector blocks