Specifications
5/2/13 888-2500-001 2-15
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
DAX-1/DAX-3
•HV (black) to terminal closest to sidewall
•LV (red) to middle terminal
•Common (white) to terminal farthest from sidewall
•Ground (green) to E1 stud (on sidewall just below CB1) for safety
ground
STEP 6 Replace CB1 cover
Figure 2-6
Transformer Power Cable Connections to CB1 & E1
(As viewed from the rear)
At this point the AC wiring is complete, however, it is not recommended to engergize
the AC mains supply or CB1 at this time. Upon completion of the required steps prior to
the section "2.4 Initial Turn On" on page 2-23 of this manual, the AC mains my be
turned on according to that section.
E1 Safety
Ground Stud
HV Terminal
LV Terminal
Common
Terminal
(Black)
(Red)
(White)
(Green)