5/2/13 888-2500-001 2-11
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
DAX-1/DAX-3
Figure 2-4
Main Transformer Schematic
STEP 3 Connect the AC mains input safety ground wire to the E5 safety ground
stud within the transformer enclosure (see Figure 2-5 below), labeled
"Earth Ground"
Once the primary side of the Main Transformer has been connected, the secondary
output can be connected to the DAX transmitter via the included 15’ 4-conductor Power
Cable. If a length change is required, additional ring lugs are included.
STEP 4 Attach Power Cable to secondary terminals as follows
Black to HV terminal
Red to LV terminal
White to Common terminal
Green to E5 safety ground stud
STEP 5 Route the cable toward the DAX transmitter, and proceed to the next
section, "2.3.4.2 Transmitter AC Connection"
Common
LV
HV
+5%
0
-5%
220
230
240