Specifications

2-2 888-2500-001 5/2/13
WARNING: Disconnect primary power prior to servicing.
DAX-1/DAX-3
Section 2 Installation
The size of the basic cabinet is 19" wide by 27.94" high by 22.88" deep. Keep in mind
that a minimum of 24 inches should be allowed for maintenance access from both the
front and rear of the cabinet.
The included NEMA enclosed transformer weighs approximately 97 pounds (43 kg)
for the DAX-1, and 162 pounds (73 kg) for the DAX-3 unit.
2.2.3 Factory Test Data
Locate and retain the FACTORY TEST DATA. During installation and initial turn on
procedures, reference will be made to FACTORY TEST DATA. This data is normally
packed in an envelope and may be inserted in the technical manual, or may be packed
with the Transmitter. This data includes meter readings, measured performance data,
information and data measured with external equipment, frequency determined parts
and adjustments specifically for your Transmitters operating frequency.
2.3 Installation
!
CAUTION:
ALL CONNECTIONS REFERRED TO IN THIS INSTALLATION PROCEDURE
SHOULD BE VERIFIED USING THE SCHEMATICS SUPPLIED WITH THE
TRANSMITTER. THE SCHEMATICS SHOULD BE CONSIDERED THE MOST
ACCURATE IN CASE OF A DISCREPANCY.
The installation section contains the information related to cabinet placement, inter-
cabinet wiring, static checks, application of low-voltage and initial turn-on and initial
adjustments of the system.