Specifications

6-16 888-2500-001 5/2/2013
WARNING: Disconnect primary power prior to servicing.
DAX-1/DAX-3
Section 6 Troubleshooting
6.2.2.5 VT100 - Page 5
!
CAUTION:
CHANGING PARAMETERS ON THIS PAGE CAN CAUSE PERMANENT
DAMAGE TO THE TRANSMITTER IF SUBSEQUENT PROPER SETUP
PROCEDURES ARE NOT PERFORMED.
NOTE:
This section is primarily for informational purposes only. The only parameters
that might be altered would be those indicated as part of a procedure described
within this manual.
Figure 6-7
VT100 Page 5 View
6.2.2.5.1 SETUP
(A) Frequency: Pressing ‘A’ will allow the user to raise or lower the desired carrier
frequency for the transmitter using the UP/DOWN arrow keys. When the carrier
frequency is changed, an output filter alignment, exciter alignment, and potential
change of the Exciter/Controller FD Filter Board is required.