Specifications

5/2/2013 888-2500-001 6-15
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
DAX-1/DAX-3
(U) Remote Power Limit: Remote power limit establishes the maximum output power
of the transmitter when the RMT POWER LIMIT SEL input on the External I/O
customer interface is active. Pressing ‘U’ will allow the user to raise or lower the power
limit using the UP/DOWN arrow keys.
(V) Digital Mode Analog BW: Digital Mode Analog Bandwidth sets the amount of
frequency content required for the adaptive ePDM filter correction to equalize. This
setting must match the Analog Modulation bandwidth setting in the DEXSTAR exciter
or audio processor. Pressing (V) toggles between 5kHz, 8kHz, and DRM.
IMPORTANT:
This setting is critical for the ePDM Correction to operate properly. Selection of
5kHz, 8kHz or DRM is available, and must be made before the "training" process
which is accessed via the VT100 Page 5 (K) prompt and described in "6.2.2.5.1
SETUP" on page 6-16 below.