Specifications

5/2/2013 888-2500-001 6-11
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
DAX-1/DAX-3
6.2.2.3 VT100 - Page 3
Figure 6-5
VT100 Page 3 View - Fault Log
NOTE:
See "6.4 Fault Log Listing" on page 6-27 of this chapter to view the complete
listing of possible DAX transmitter faults. This table also includes a description
of each fault and an explanation of the transmitters response to the fault.
INDEX – Up to 75 faults can be logged into the circular fault log. When 75 has been
reached the oldest fault will be discarded when a new fault occurs.
TYPE – Indicates the name of the fault logged.
STATUS – Indicates whether the fault is still present (ACTIVE), or is no longer present
(INACTIVE).
OCCUR TIME – Logs when the fault occurred relative to the present time. Example:
If the occur time is 0002:10:00 the fault occurred 2 hours and 10 minutes ago.
CLEAR TIME - Logs when the fault cleared relative to the present time. Ex. If the
clear time is 0002:01:00 the fault occurred 2 hours and 1 minutes ago.