Specifications
5/2/2013 888-2500-001 6-5
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
DAX-1/DAX-3
6.2.2.1 VT100 - Page 1
Figure 6-3
VT100 Page 1 View
6.2.2.1.1 SYSTEM
Forward Power: Transmitter output power measured using an RF detector on the
Output Monitor board. Forward power is limited to 115% of rated power.
NOTE:
Forward power detector calibration is available using (3) on VT100 page 5 (see
"6.2.2.5 VT100 - Page 5" on page 6-16).
Reflected Pwr: Reflected power to the transmitter measured using a detector on the
Output Monitor board. Instantaneous reflected trip point is factory set to 100W per PA
module.
NOTE:
Reflected power detector null and calibration is available using (4) & (5) on
VT100 page 5. Average reflected power trip is set using (I), also on VT100 page
5, to 70W per PA module (see "6.2.2.5 VT100 - Page 5" on page 6-16).
VSWR: Voltage standing wave ratio. Example: 1.009 reading indicates 1.009:1 ratio.
DC Voltage: High voltage power supply (B+) voltage measured via B+ Sample board.
Voltage range is 100V – 300V and varies with power level setting.