Installation Instructions
INSTALLATION INSTRUCTION 
FOR 
OFF STUD JOINERS 
 FiberCementSidingcanbejoinedoff‐studusingthespeciallydesignedmetaljoiner.
OFF STUD JOINER
 Theverticaljointsoftheplanksshalloccurattheframingmembersorbetweentheframingmemberswhenan
offstudjoinerisplacedontheplankend.Theoffstudjoinerispositionedsothatthebottomlipisrestingonthe
adjacentsolidcourseofplanks.The
plankisthenfastenedtotheframing.Theabuttingplankispositionedand
fastenedintoplaceinsuringthattheloweredgesofthetwoplanksalign.Theoffstudjoinerislocatedcentrallyover
thejoint.Restrictionsontheoffstudjoinerlocationsarefollows:
a)  Allsplicesshallbe
locatedaminimumoftwostudcavitiesfromwallcorner.
b)  Successivespliceswithinthesameplankcourseshallbelocatednocloserthan48”from
oneanother.
c)  Allsplicesshallbestaggeredatminimum2‐footintervalswhenlocatedinthesamewall
cavity.
d)  Splicesshall
beatleastonestudcavityawayfromdooropenings.