System information
Simplex Time Recorder Co. 7 S4010-0001-4 4/00
Category Model* Description Voltage Color
4010-9101 Beige
4010-9102
120 VAC
Red
4010-9201 Beige
4010-9202
4010 Fire Alarm Control Panel with: door,
cabinet, power supply/battery charger, IDNet
interface, 4 NACs, 2 auxiliary relays, and external
N2 communications interface
240 VAC
Red
Control Panel
Assembly
(select one)
4010-9150
4010 Fire Alarm Control Panel electronics only,
for pre-shipped cabinets, requires door
120 VAC NA
Optional Expansion Slot Features (two slots are available, select modules as required)
Category Model Description
4010-9810 DACT Module (Common Event Reporting)
4010-9816 DACT Module (Point Reporting)
Includes two, 7 ft long RJ45 cables
4010-9821 4120 Network Interface Module with fixed, wired connections
Reporting and
Network
Modules
(select one)
4010-9817 4120 Network Interface Module, Modular, requires 2 media modules
4010-9811 Dual RS-232 Interface Module
RS-232
Communications
(select one)
4010-9812 Single RS-232 Interface Module with Service Modem connection
4010-9818 4120 Network Wired Media Module
Media Modules
(select 2 if using
4010-9817)
4010-9819 4120 Network Fiber Optic Media Module
Media modules mount on the 4010-9817
module without impact to slot allocation
space.
Chassis Mounted Expansion Modules (select as required)
Category Model Description
4010-9813 120 VAC input
4010-9823
4 A Expansion Power Supply
240 VAC input
4010-9814 120 VAC input
Additional
Power Supply
(select one)
4010-9824
Suppression Release Power Supply, 4 A @ 24 VDC,
regulated ± 10%, includes front panel suppression system appliqué
240 VAC input
4010-9820 Battery Meter Module, Ammeter and Voltmeter
Optional
Features
(select one)
4010-9825
24 VDC Expansion Power Distribution Module, provides two additional termination points
for an expansion power supply tap or the auxiliary power output
4010-9806
Dual Circuit Class A (Style Z) NAC Adapter Module, 2 maximum
4010-9809 Dual Circuit City Connect Module
Optional
Features
4010-9829 Dual Circuit City Connect Module w/o disconnect switches
select 1 maximum
Accessories (select as required)
Category Model Description
4010-9826
120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 1/2 A @120 VAC,
select as required, 2 maximum
2975-9801 Semi-flush trim, beige, 1 7/16” (37 mm) wide
Optional
Features
2975-9802 Semi-flush trim, red, 1 7/16” (37 mm) wide
2081-9272
6.2 Ah Battery, 12 VDC, 2 required
2081-9274
10 Ah Battery, 12 VDC, 2 required
2081-9288
12.7 Ah Battery, 12 VDC, 2 required
2081-9275
18 Ah Battery, 12 VDC, 2 required, Note: use will not allow bottom entry conduit
Batteries
(required if
batteries are
internal, select
one size)
2081-9287
25 Ah Battery, 12 VDC, 2 required
2975-9215 Red Cabinet
Cabinets
(select one if
pre-shipped)
2975-9214 Beige Cabinet
Dimensions: 22” H x 18” W x 5 3/8” D
(559 mm x 457 mm x 137 mm)
4010-9858 Red Door
Doors
(select one if
pre-shipped)
4010-9857 Beige Door
Dimensions: 22” H x 18” W x 7/8” D
(559 mm x 457 mm x 22 mm)
* ULC listed models are designated by a “C” or “CF” suffix such as 4010-9010C or 4010-9101CF. “CF” indicates French labels. Contact your
local Sim
p
lex re
p
resentative for details.
4010 Fire Alarm Control Selection Chart and Module Location Rules (refer to diagrams on next page)