Specifications
Section 4: Telephones and Optional Equipment
4-54 ◆ Section 4: Telephones and Optional Equipment Aspire S Hardware Manual
Installing the Power Failure Telephones:
1. Connect an RJ-61 connector to the CN5 connector on the COIU PCB installed in the Aspire S.
2. Install a modular jack for the single line telephone supporting PF operation. The modular jack
should be within six feet of the phone.
3. Run one-pair 24 AWG station cable from the cross-connect block to a modular jack.
4. Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads to the
jack.
RJ61 Cable Connector - CN5
The CN5 connector is polarity sensitive (tip to tip, ring to ring).
Pin No. Connection
1-
2 SLT Interface
Power Failure Circuit - Tip
3 Circuit 2 - Tip
4 Circuit 1 - Ring
5 Circuit 1 - Tip
6 Circuit 2 - Ring
7 SLT Interface
Power Failure Circuit - Ring
8-
12345678