Technical data

SimpleComTools, LLC COM1000 – AT Commands
SimpleComTools, LLC 9
*485RECIPIENT
n, n, n, n … = Desired message recipient(s) as detailed in Message Config
registers. (Comma separation for multiple, ie 1,2,3,4,5,6,7,8) Max number = 8.
*485STREAM1 Serial Data Stream used to trigger events (Up to 20 characters)
*485STREAM2 Serial Data Stream used to trigger events (Up to 20 characters)
*485STREAM3 Serial Data Stream used to trigger events (Up to 20 characters)
*485TCPDESTIP
IP or Domain of TCP Packet Destination x.x.x.x or abc.123.com (Up to 50
characters)
*485TCPDESTPORT
TCP Packet Destination Port = nnnnnn
(5 digit value with range between 1 and 65535)
*485TCPIATIMER
TCP inactivity timer. Device will drop TCP connection if there is no data flow for
that period of time. (n =0-255 Seconds)
*485TCPRETRIES
The number of TCP Retries. Number of times to retry making a connection to the
TTCPDESTIP remote IP address after a failed connection attempt.
*485TCPSERVER TCP/Device Server Application:
*485TCPSESSTIME
TCP Session connection timer. TCP Client will drop TCP connection after the
stated period of time. (n =0-255 Seconds)
*485TCPSVRPORT
TCP/Device Server Application Port. = nnnnnn
(5 digit value with range between 1 and 65535)
*485TCPSVRTIMER
TCP/Device Server inactivity timer. Device Server will drop TCP connection if
there is no data flow for that period of time. (n =0-255 Seconds)
*485TIMER1 Timer: (n = # Minutes)
*485TIMER2 Timer: (n = # Minutes)
*485TIMER3 Timer: (n = # Minutes)
*485TRIG1 RS485 Application #1 Trigger;
*485TRIG2 RS485 Application #2 Trigger;