Technical data

SimpleComTools, LLC COM1000 – AT Commands
SimpleComTools, LLC 18
*RNAME
Customized RELAY Interface Name. A free-text field for the NAME of the
interface which will be used in all UDP, TCP, SMS, and SMTP messages. (Up to
20 characters)
*ROFFALIAS
Customizable Relay ON command. This is a free-text field to be used to create a
term to be interpreted as the *ROFF AT Command. (Accepts up to 20
characters)Example: 'AT*ROFFALIAS=engine-off' would allow for the term
'engine-off' to be used as a command to DE-ENERGIZE the relay.
*ROFFAUTO
Relay Auto-Off Timer; Interval of timer the relay will stay energized after being
turned on.
*ROFFMSG
Customized Relay De-energized State message. (Up to 20 characters) A free-
text field used when the Relay is in the active state. Text is used in all UDP,
TCP, SMS, and SMTP messages. For SMS and SMTP, this will be seen as the
SUBJECT field.
*RONALIAS
Customizable Relay ON command. This is a free-text field to be used to create a
term to be interpreted as the *RON AT Command. (Accepts up to 20
characters)Example: 'AT*RONALIAS=engine-off' would allow for the term
'engine-off' to be used as a command to ENERGIZE the relay.
*RONMSG
Customized Relay Energized State message. (Up to 20 characters) A free-text
field used when the Relay is in the active state. Text is used in all UDP, TCP,
SMS, and SMTP messages. For SMS and SMTP, this will be seen as the
SUBJECT field.
*RRECIPIENT
Desired message recipient(s) as detailed in Message Config registers.
Comma separation for multiple, (ie 1,2,3,4,5,6,7,8). Max number = 8.
*RSCHDOM
Sets the DAY OF MONTH for regularly scheduled relay triggering. Set this value
if you do NOT want the relay to be triggered every day. Otherwise, the default
value of 0 will ensure this happens daily.
Options: 0 = Every Day (DEFAULT)
1-31 = Day of the Month. (1=1
st
day, 2=2
nd
day, etc)
Note: Triggering once-per-month requires that DAY OF WEEK be set to ‘0’.
*RSCHDOW
Sets the DAY OF WEEK for regularly scheduled relay triggering. Only set this
value if you do NOT want the relay to be triggered every day. Otherwise, the
default value of 0 will ensure this happens daily.
Options: 0 = Every Day (DEFAULT)
1-7 = Day of the Week starting with Sunday. (Sun=1, Mon=2, etc)
Note: Requires the value DAY OF WEEK or DAY OF MONTH be set as well.
*RSCHTIMER
Sets the time interval for recurring relay triggering to take place within the same
24-hour period. This requires that the value *ROFFAUTO also be set, or else the
relay will stay on after the first trigger.
Options: 0 = no timer active (DEFAULT)
1-1440 = number of minutes between relay triggers