Technical data

SimpleComTools, LLC COM1000 – AT Commands
SimpleComTools, LLC 17
*MPASSWORD
AT*MPASSWORD=xxxxxx Sets the dialup or PPP Password, where 'xxxxxx' is
any alphanumeric character stream up to 20 characters. Acceptable characters
include A-Z, 0-9, and - or _. Characters ~ ! @ # $ % ^ & *,.; are invalid.
*MUSER
AT*MUSER=xxxxxx Sets the dialup or PPP Uername, where 'xxxxxx' is any
alphanumeric character stream up to 20 characters. Acceptable characters
include A-Z, 0-9, and - or _. Characters ~ ! @ # $ % ^ & *,.; are invalid.
*NETMASK
x.x.x.x = IP address subnet mask used to determine what subnet an IP address
belongs. Examples include: 255.255.255.0; 255.255.240.0; 255.255.0.0, etc.
Consult your Network Administrator for the appropriate SUBNET MASK value.
*PASSWORD
AT*PASSWORD=xxxxxx Sets the device Password, where 'xxxxxx' is any
alphanumeric character stream up to 20 characters. Acceptable characters
include A-Z, 0-9, and - or _. Characters ~ ! @ # $ % ^ & *,.; are invalid. This will
be the secret password used at the serial or Telnet command prompt. Factory
default password is 'SIMPLE' (uppercase).
*PKTFORMAT
Select a packet format for UDP/TCP application messages.
Options: 0 = Data Only (DEFAULT)
1 = Message Only
2 = HostName, Data
3 = Date/Time, Data
4 = HostName, Date/Time, Data
5 = HostName, Date/Time, Message, Data
6 = Use Status
7 = Raw Data
*PINGIP
x.x.x.x or abc.123.com
IP or Domain of remote destination where the device will PING to ensure a PPP
connection is still active. (Up to 50 characters)
*PINGRETRIES
Number of times to PING the remote destination IP or Domain during a PING
event. This number should be tuned to guarantee at least one PING success
during an event. (5 digit value with range between 0 and 65535)
*PINGTIMER
Number of minutes to wait before the next PING attempt.
Options: 0 = PING if Off (DEFAULT)
1-65535 = Number of Minutes to wait before next attempt
*PROTECT
Enable/Disable PROTECTED mode. Protected Mode restricts access to the
device.
Options: 0 = Disabled (DEFAULT)
1 = Enabled
NOTE: When Protected Mode is enabled, the '>' symbol will now be shown as
the as command the prompt. Pressing the ENTER key will result in a password
challenge. To access the device, enter the device password.
*RELAY
Displays current state of RELAY. Command followed by =n will execute that
value.