Technical data
SimpleComTools, LLC COM1000 – AT Commands
SimpleComTools, LLC 14
*FTPUSER Primary FTP Server Account Username;
*GATEWAY
x.x.x.x = IP address of the router or computer that routes the traffic from the
COM1000 to another outside network such as the Internet. Consult your
Network Administrator for the appropriate GATEWAY value.
*GSMS
‘GET SMS MESSAGES’ (Forces COM1000 to initiate a check of the SMS
Modem/Radio to see if there are any new SMS Messages)
*GETEVENTS
Returns content of the Event Log. Will return either COUNTS and/or EVENT log
depending on configuration of interfaces and SCHEDULER.
*GETLOG
Returns contents of the COM100 performance log. Includes system startup,
network connections, system errors, input state changes, etc.
*HOSTNAME
Device HOSTNAME: Name to be used for domain name and as NETBIOS name
for Windows Networks Example: the hostname “computer “ would be known as
“computer” on the local Windows LAN and “computer.mydomain.com” over the
internet. *HOSTNAME accepts alphanumeric values up to 50 characters.
Acceptable characters include A-Z, 0-9, and – or _. Characters ~ ! @ # $ % ^ &
*,.; are invalid.
*I1 Current Digital Input 1 Status; (Query ONLY)
*I1ACTIVEACTION
Digital Input 1 ACTIVE EVENT action. This is the event that will be triggered
when the switch connected to the digital input changes to the ACTIVE state.
*I1ACTIVEMSG
Customized Digital Input 1 Active State message. (Up to 20 characters) A free-
text field used when the switch is in the ACTIVE state. Text is used in all Serial,
UDP, TCP, SMS, and SMTP messages. For SMS and SMTP, this will be seen
as the SUBJECT field.
*I1ACTIVENAME
Customized Digital Input 1 Active State name. (Up to 20 characters) A free-text
field used when the switch is in the ACTIVE state. Name will be used in all UDP,
TCP, SMS, and SMTP messages. For SMS and SMTP, this will be seen as the
SUBJECT field.
*I1COUNT Reports current count of Digital Input 1 (Query ONLY)
*I1INACTIVEACTION
Digital Input 1 INACTIVE EVENT action. This is the event that will be triggered
when the switch connected to the digital input changes to the INACTIVE state.
*I1INACTIVEMSG
Customized Digital Input 1 Inactive State message. (Up to 20 characters) A
free-text field used when the switch is in the INACTIVE state. Text is used in all
Serial, UDP, TCP, SMS, and SMTP messages. For SMS and SMTP, this will be
seen as the SUBJECT field.