Technical data

SimpleComTools, LLC COM1000 – AT Commands
SimpleComTools, LLC 12
*AUDPDESTPORT
UDP Packet Destination Port = nnnnnn
(5 digit value with range between 1 and 65535)
*AVALRESET Reset COUNTER value after reporting
*AVOLTMAX Highest voltage output of the chosen sensor.
*AVOLTMIN Lowest voltage output of the chosen sensor.
*AWARNRECPT
Desired message recipient(s) as detailed in Messaging Config registers. =[n, n,
n, n … ](Comma separation for multiple, ie 1,2,3,4,5,6,7,8) Max number = 8.
*CLEARCOUNTS Sets all the Digital Inputs back to ‘0’.
*CLEAREVENTS Erases the COM1000 EVENT log. New log will begin immediately.
*CLEARLOG Erases the COM1000 performance log buffer. New log will begin immediately.
*DATE Set DATE: MM/DD/YYYY
*DDNS Forces DDNS update to DDNS server
*DDNSIP
IP or Domain Name of Dynamic Domain Name System (DNS) Server.
Accepts n.n.n.n or abc.123.com (Up to 50 characters)
*DDNSPASS DDNS Account Password;
*DDNSPORT
DDNS Server Port = nnnnnn
(5 digit value with range between 1 and 65535) (Default is 53)
*DDNSTIMER
Sets the update interval update interval for timed updates to DDNS server
Options: 0 = not active (DEFAULT)
1-65535 = number of minutes between updates
*DDNSTYPE
Dynamic DNS Server Protocol or Service.
Options: 0 = DDNS Not Used
1 = DTDNS.COM
2 = SITESOLUTIONS.COM
3 = DYNDNS.ORG-DYNAMIC
4 = DYNDNS.ORG-CUSTOM
5 = DYNDNS.ORG-STATIC