Installation manual

SimpleComTools, LLC App Note: COM1000 – Wiegand Card Readers
7/27/2006 Simple Com Tools, LLC Page 8 of 9
Reviewing and Editing the Card Access List
To view and edit the Card ID Access List, follow these steps:
Step 1
:
Type AT&V=5. This will display the WIEGAND configuration parameters:
>AT&V=5
---------------
WIEGAND
---------------
*WAPP1:1
*WAPP2:6
*WAPP3:0
*WTRIG1:1
*WTRIG2:2
*WTRIG3:0
*WBUFFER:0
*WREPORT: 0
*WUDPDESTIP:0.0.0.0
*WUDPDESTPORT:0
*WTCPDESTIP:0.0.0.0
*WTCPDESTPORT:0
*WEVENTMSG:
*WRECIPIENT:0
CARDID01:35724
CARDID02:35730
CARDID03:0
CARDID04:0
CARDID05:0
CARDID06:0
CARDID07:0
CARDID08:0
Etc…
Step 2
:
To delete a Card ID value, enter AT*CARDIDxx=0.
To change a Card ID value, enter AT*CARDIDxx=nnnnn.
(xx = the Card ID number to change, and nnnnn is the serial number. Acceptable Card IDs range from 0- 65535).
Examples:
Delete a value: AT*CARDID01=0
Change a value: AT*CARDID01=12345
Step 3
:
Save the new value settings and reset the device.
>AT&W
Changes will take effect after reboot
>ATZ
Step 4
:
Type AT&V=5 to verify the changes.