Installation manual

SimpleComTools, LLC App Note: COM1000 – Wiegand Card Readers
7/27/2006 Simple Com Tools, LLC Page 4 of 9
Wiring Diagram
Configuring the COM1000 to Communicate with the Card Reader
After installation of the reader, connect the COM1000 to a computer to the TERMINAL port using the RS232 serial
cable. You will now configure the COM1000 to interface with the card reader and develop the access list.
Step 1
:
Connect to the COM100 TERMINAL port using a terminal program, such as HyperTerminal.
The default baud rate is 115200, 8N1. HW flow control is not necessary.
Step 2
:
Obtain the COM1000 command prompt using the ENTER command.
COM1000 (c) 2003 SimpleComTools
May 04 2006 C1000.2005.29.W128
>
Step 3
:
Type AT&V=5.
This will provide the COM1000/Wiegand card reader settings.
*WAPP1:0
*WAPP2:0
*WAPP3:0
*WTRIG1:0
*WTRIG2:0
*WTRIG3:0
*WBUFFER:0
*WREPORT: 0
*WUDPDESTIP:0.0.0.0
*WUDPDESTPORT:0
*WTCPDESTIP:0.0.0.0
*WTCPDESTPORT:0
*WEVENTMSG:
*WRECIPIENT:0
*CARDID01:0
*CARDID02:0
*CARDID03:0
Etc…
Optional
Unused
Unused
Unused
Black
Shield
Red
Orange
Green
White
Yellow
Brown
Blue
Violet