Operation Manual
Switch on the ECU
Without remote controller
Afterturningonthebatterypower,theECUwillbeactivatedand1beepwillbeaudible.Iftheremotecontroller
hasnotbeenrecognized,theECUwillturnintosleepingmode.Powerconsumptioninstandbymodewillbe90mA.
With controller
Whentheremotecontrollerhasbeenrecognized,theECUwillbeactivated.TheECUwilltesttheRelayand
Fetsbyswitchingtherelayonando.After1beepthecoolfan’swillbeactivated.Powerconsumptionwillbe
330mA.Whentheremotecontrollerhasbeenswitchedo,theECUwillenterautomaticallythestandbymode.
Safety features of the ECU
Switching o the remote controller
WhenyouswitchotheremotecontrollertheECUwillenterautomaticallythestandbymode.
Theremotecontrollerwillautomaticallyshutoafteratimeoutof60seconds.
Temperature protection
TheECUwillentertheerrormodewhenthePCboardhasreachedatemperatureof+/-75degreesCelcius.
Seealsothesummaryoferrors.TheECUwillresetautomaticallywhenthetemperaturedropswith15degrees.
Low voltage protection
TheECUwillentertheerrormodewhenthevoltagedropsunder9Volt.Seeerrorsummary.
After30secondstheECUwillresetincasethevoltagebecomeshigherthan9volt.
Status legend
24
Status Number of beeps Cooling fan
ActivationofECU 1x O
Recognizing of remote controller 1 x On
Towhookdetection 1persecond O
Switch next to antenna for resetting
the remote controller 2 x --
Error
Maximum current level per motor.
Immediatelydisconnected@+-210A.
After2sec.disconnected@150A Beepsalvo3secondslongpermotor
Number of beeps per 2 seconds
Motor (detection) error 3 x
“Fets” error 4 x
Temperatureabove75degrees 5x
Battery voltage lower than 9 V 6 x
NL
UK