Operation Manual
1 x Left mover-unit
1 x Right mover-unit
1 x Connection bar, 2x mounting clamps assemblies
1x Electroniccontrolunitandhandset,(incl.terminalblock6and3pins,2xAAbatteries,antenna18cm
1 x 1.5 mtr. red cable 10 mm
2
/ 1x 1 mtr. black cable 10 mm
2
, 1x main power switch
4x Terminalconnectors,4xtiewraps,1xdistancemeasuringblockof1.5cm
1 x Extendable wrench (only manual version)
1x 5mtrs.exibleprotectionhose
1 x Caution sticker “Release rollers”
Easymatic version:
1x Hydraulic system, including protection cover
1x Multiplex plate 15x15 cm
1x 1x 1 mtr. red cable 1 mm
2
/1x10Amp.fuse/1xfuseholder/1xpowermainswitch
1x 1x 4 mtr. purple cable and 1x 4 mtr. brown cable 1 mm
2
1x AllenkeyM6
NL
UK
1. SCOPE OF DELIVERY
• InstalltheSimPark®moverprefferablyonthefrontsideoftheaxle.
• Measurethedistancebetweenthechassisatthelocationoftheinstallation.
• Measurethelengthoftheconnectionbarandmarkthecenterwithamarker(75 cm).
• Assembletheleftandrightmoverunittogetherbymeansoftheconnectionbarandbesurethatthe
2. INSTALLATION MANUAL
• Placethemountingclamps(see g. 2 ) over the connection bar and apply the topplates on the clamps.
• Useasupporttopressthecompletemoversystemagainstthechassisofthecaravanandslidethetwo
mountingclampsoverthecaravanchassis.SimPark®hasseveralmountingplatesfordierenttypesof
caravan chassis.
• Adjustthedistancebetweenthetyreandthedriverolleratmin.15mm-max.20mm.Usethesupplied
measuring block. In case of high pressure tyres has been tted (4.5 bar) the distance between the tyre
andthedriverollershouldbe20mm.Thisappliesonlytothemanualversion.
In case the installation takes place while the tyres are lifted from the oor, you have to pay attention that
the distance between the caravan and the drive roller can be changed when it’s set back on the oor due
to the inuence of the weight of the caravan.
g. 1
16
L. max = 2450 mm L. min = 1870 mm
Mark