User guide
186 DC 900-1338I
Protocol Software Toolkit Programmer Guide
from the link in the area that follows the protocol header. The data area contains the
data read. The stop character and CRC characters are not provided.
DLI_OPT_ARGS.usFWPacketType n/a
DLI_OPT_ARGS.usFWCommand n/a
DLI_OPT_ARGS.usFWStatus n/a
DLI_OPT_ARGS.usICPClientID n/a
DLI_OPT_ARGS.usICPServerID n/a
DLI_OPT_ARGS.usICPCommand DLI_ICP_CMD_READ
DLI_OPT_ARGS.iICPStatus n/a
DLI_OPT_ARGS.usICPParms [0] n/a
DLI_OPT_ARGS.usICPParms [1] n/a
DLI_OPT_ARGS.usICPParms [2] n/a
DLI_OPT_ARGS.usProtCommand DLI_PROT_SEND_NORM_DATA
DLI_OPT_ARGS.iProtModifier n/a
DLI_OPT_ARGS.usProtLinkID Link ICP read data from.
DLI_OPT_ARGS.usProtCircuitID n/a
DLI_OPT_ARGS.usProtSessionID Session ID (See attach, Section 9.2.3 on page 164)
DLI_OPT_ARGS.usProtSequence n/a
DLI_OPT_ARGS.usProtXParms [0] n/a
DLI_OPT_ARGS.usProtXParms [1] n/a
Figure 9–20: Receive Data from ICP Response