User`s guide
2: BSCTRAN Commands and Options
DC 900-1406E 31
2.4 SET Command
The SET command has the following format:
SET link# server[_ICP#] [/PARn[=d]] [/PARn[=d]...]
[/START] [/STOP]
The SET command sets up the configurations of the link (link#) on the ICP board
(
ICP#).
The
SET command options are as follows:
/PARn[=d] This option specifies the value of configuration parameter
n,
where
n = 1 through 30, and d = 0 through the maximum
allowed value for the particular parameter
n. If d is omitted,
BSCTRAN will prompt the user with the allowed values. For a
complete description of the link configuration parameters, see
the BSC Programmer’s Guide.
/START This option starts the specified link. The
START option may be
used with the
/PARn=d options. A link must be started before
attempting to send or receive files. An attempt to start a link
that is already enabled will be rejected. If the error
Link not
started is reported by BSCTRAN, and a SHOW command indi-
cates the link status as
STARTING, this means that the Data Set
Ready (DSR) signal has not been received from the remote
computer. This error can be suppressed by using the
SET
/PAR16=2 or SET /PAR16=3 command to instruct the ICP to
ignore the DSR signal.
/LOCKSTART This option is identical to the
/START option with the exception
that the link stays enabled until a
SET /STOP (disable) command
is sent, even if the disable is not sent by the current process.