User guide
A: Installation at a Glance
DC 900-1333P 213
Step 8: Build the loopback tests (except the example SRA) page 90
cd C:\freeway\client\test\ppp
a. Edit the client TSI configuration file (
pppaltcfg
1
), changing the default value
of the Freeway
server parameter, freeway_0, to the name (or Internet
address) of your current Freeway server.
b. If you are using AWS, BSC, or FMP on a Freeway 1100/1150/1200/1300, edit
the DLI configuration file (
pppaldcfg), setting the ElecInterface parameter to
the correct electrical interface.
c. Run the make file:
nmake -f makefile.ant all (for an Alpha NT system)
nmake -f makefile.int all (for an Intel NT system)
The newly created files will be placed in the freeway\client\op-sys\bin direc-
tory.
Step 9: Modify the Freeway system boot parameters page 93
Modify the path name for the
System Boot Directory. Log in to Freeway. From the
Freeway Interactive Menu, select “Modify Configuration,” then select “Modify
Boot Parameters.”
Step 10: Boot Freeway to download the software page 94
To boot Freeway from the Freeway Interactive Menu, select “Shutdown Options,”
then select “Reboot Server.”
1. The Military/Government protocol uses miltcfg. X.25 uses apitcfg.