User`s guide
4: FMP Link Configuration Options
DC 900-1339H 95
4.21.2 Example for the Freeway 1000 Platform
The Freeway PCLK frequency equals 3.6864 x 10
6
for the Freeway 1000.
An example follows for 14400 bits per second:
4.22 Electrical Interface Option (40)
The electrical interface option applies to the Freeway 1000 model only and allows the
electrical interface for each link to be set. The valid values are EIA-232 (default),
EIA-485, EIA-530/EIA-449 (balanced, EIA-422), V.35, EIA-449 (unbalanced, EIA-423),
and EIA-562. Refer to the ICP2424 Hardware Description and Theory of Operation guide
for more information on electrical interfaces and cabling options.
To set this option using the DLI configuration file, use the
elecInterface parameter;
for example,
elecInterface = “EIA232”. See Table 5–1 on page 104.
V
3684400
14400 32×
---------------------------2–=
V 82–=
V 6=