User`s guide

70 DC 900-1339H
FMP Programmer’s Guide
4.2.2 Internal
When the internal clock setting is used, the clock signal is generated at the rate specified
in the data rate option (Section 4.1). The generated clock signal is used for transmit
clocking and is output on the terminal timing signal (EIA-232 pin 24). Receive clocking
is input through the receiver timing signal (EIA-232 pin 17). The transmitter timing
signal (EIA-232 pin 15) is not used. Your Freeway server is factory configured for
external clocking using a hardware jumper. If you need to set internal clocking, call the
Simpact customer support number given in the Preface.
4.3 Number of Leading SYN Characters Option (4)
This option specifies the number of SYN characters to precede all transmitted data
blocks. Certain links may require more SYN characters to ensure synchronization on
poor-quality lines. The minimum number of leading SYN characters is two; the maxi-
mum number is eight. SYN characters are not added to unstructured asynchronous
transmissions.
To set this option using the DLI configuration file, use the
numLeadSync parameter; for
example,
numLeadSync = 3. See Table 5–1 on page 104.
4.4 Protocol Option (5)
This option indicates the protocol used on the ICP and has only one setting (FMP).
This setting is reported in the configuration report (Section 3.4.2.2 on page 54) which
may be used by client application programs to verify the protocol running on the ICP.
The DLI configuration program (Chapter 5) considers this protocol option to be pro-
tocol-independent, but it must be set to
“FMP” in order to select the FMP protocol. This
parameter must be set prior to any attempt to assign another FMP configuration option
within a session definition (see Figure 5–2 on page 103); otherwise the DLI configura-
tion program will fail.