DC 900-1339H 119
9 –109 DLI_ICP_ERR_XMIT_TIMEOUT The protocol software was unable to trans-
mit the data. This error occurs when some
or all of the modem signals are not present.
10 –110 DLI_ICP_ERR_DSR_UP The protocol software has received a posi-
tive data set ready (DSR) signal from the
remote station.
11 –111 DLI_ICP_ERR_DSR_DOWN The data set ready (DSR) signal from the
remote station was lost. All polling and data
transfer operations are stopped.
23 –112 DLI_ICP_ERR_BAD_PARITY The protocol software has detected a parity
error or errors.
25 –113 DLI_ICP_ERR_RCV_OVERFLOW The protocol software did not process a
character before the next character was
received. This can be caused by high data
rates on several of the links.
27 –114 DLI_ICP_ERR_BUF_OVERFLOW A message larger than the transmis-
sion/receive buffer (Section 4.7 on page 72)
was received. Some data was lost.
43 –115 DLI_ICP_ERR_BUF_TOO_SMALL The ICP message buffer size (Section 3.4.1.3
on page 48) is smaller than the buffer
received from the client.
77 –117 DLI_ICP_ERR_LINK_ACTIVE The link is already started.
79 –118 DLI_ICP_ERR_LINK_INACTIVE The link is stopped.
74 –119 DLI_ICP_ERR_BAD_SESSID If this error occurs, please call Simpact.
— –120 DLI_ICP_ERR_LINK_NOT_CONFIG The device is not owned; no legal opera-
tions.
72 –121 DLI_ICP_ERR_NO_SESSION No more clients are available on this ICP.
This error should never occur; if it does,
please call Simpact.
76 –122 DLI_ICP_ERR_BAD_PARMS The parameter value(s) used for the func-
tion call are illegal.
73 –123 DLI_ICP_ERR_BAD_MODE The function request is not available for the
requested access mode; see Table 2–2 on
page 33.
Table C–1: FMP Error Codes (Cont’d)
5-byte
Header
Code
Freeway
Code DLI Constant Name Meaning
Techpubs —
The 3 missing
codes in
column one
are OK, per
Fred Dickson.