User`s guide
34 DC 900-1349B
BSCDEMO User’s Guide
Received ATTACH COMPLETE (46) from link 4
Received ATTACH COMPLETE (46) from link 5
bscdemo> c/p11 4 ! Configure master station
P11 (STATION STATUS): 0=SLAVE 1=MASTER (0 to 1): 1
bscdemo> r 4
Received CONFIGURATION (6) from link 4
bscdemo> e 4,5 ! Bind links
Received START LINK (1) from link 4
Received START LINK (1) from link 5
bscdemo> k ! Check current block sizes
Write block size = 1024
Read block size = 2048
bscdemo> k=500 ! Change write block size
Write block size = 500
Read block size = 2048
bscdemo> l4 ! Request link configuration report
Received CONFIG REPORT (14) from link 4
1 DATA RATE = 9(9600) 2 CLOCK SOURCE = 0(EXTERNAL)
3 REPLY TIMEOUT = 3 4 NUMBER SYNCS = 3
5 PROTOCOL = 0(3780) 6 PARITY = 1(ODD)
7 CHARACTER SET = 0(ASCII) 8 TRANSMIT BLOCK SIZE= 512
10 DATA TRANSLATION = 1(TABLE 1) 11 STATION STATUS = 1(MASTER)
12 SPACE COMPRESSION = 0(OFF) 13 CONVERSATION MODE = 0(OFF)
14 RETRY LIMIT = 3 16 MODEM CONTROL = 1(FDX)