User`s guide

1: BSCDEMO Commands
DC 900-1349B 13
Table 1–1: BSCDEMO Commands and Options
Command Option Description
ATTACH Attach a client to a link. Mode field values are:
0 = Master
1 = Shared Master (or Read Session for BSC 3270 or
BSC 2780/3780)
2 = Control
3 = Read Only (FMP) or Trace (BSC 2780/3780)
BIND See the ENABLE command.
BUFFER /CONFIGURE = n Configure the ICP message buffer size. BSCDEMO prompts
for n if it is omitted. The command is sent to link 0. For some
protocols, this must be the first BSCDEMO command after
download. Other protocols have a default ICP message buffer
size.
/INPUT = n Display BSCDEMOs internal input buffer from the most
recent READ from the ICP, where n is the number of bytes to
display. The entire buffer contents are displayed by default; n is
an optional argument. Display is in hex.
/OUTPUT = n Display BSCDEMOs internal output buffer from the most
recent WRITE from the ICP, where n is the number of bytes to
display. The entire buffer contents are displayed by default; n is
an optional argument. Display is in hex.
CONFIGURE Set up link configuration options. BSCDEMO prompts for
option values if they are omitted. For some options, the link
must be disabled.
/P1 = n Data rate where valid values of n (in bits per second) are:
0 = 75
1 = 110
2 = 135
3 = 150
4 = 300
5 = 600
6 = 1200
7 = 2400
8 = 4800
9 = 9600
10 = 19200
11 = 38400
12 = 56000