Installation guide

4: Commands and Responses
DC 900-1564A 55
TIME-STAMP EVENT STATUS
1240.705 TRACE ON
1240.805 DTR_1 ON
1241.005 DCD_1 ON
1241.005 DSR_1 ON
1241.005 RTS_1 ON
1241.005 CTS_1 ON
1241.015 XMT_1 5 ENQ TSN=00
1241.025 RCV_1 5 ENQ TSN=00
1241.040 RCV_1 5 ACK TSN=00
1241.040 XMT_1 5 ACK TSN=00
1241.155 RCV_1 130 TSN=01 MBI=0x00 AML=SLC_AML_A_ND
1241.155 XMT_1 130 TSN=01 MBI=0x00 AML=SLC_AML_A_ND
1241.270 RCV_1 130 TSN=02 MBI=0x20 AML=SLC_AML_B_ND
1241.270 XMT_1 130 TSN=02 MBI=0x20 AML=SLC_AML_B_ND
1241.280 RCV_1 5 AML Code=0x01 Name=SLC_AML_A_ND
1241.280 XMT_1 5 AML Code=0x01 Name=SLC_AML_A_ND
1241.305 XMT_1 5 AML Code=0x21 Name=SLC_AML_B_ND
1241.320 RCV_1 5 AML Code=0x21 Name=SLC_AML_B_ND
1241.440 XMT_1 130 TSN=03 MBI=0x00 AML=SLC_AML_A_ND
1241.450 RCV_1 130 TSN=03 MBI=0x00 AML=SLC_AML_A_ND
1241.555 XMT_1 130 TSN=04 MBI=0x20 AML=SLC_AML_B_ND
1241.565 RCV_1 130 TSN=04 MBI=0x20 AML=SLC_AML_B_ND
1241.565 XMT_1 5 AML Code=0x01 Name=SLC_AML_A_ND
1241.580 RCV_1 5 AML Code=0x01 Name=SLC_AML_A_ND
1241.580 XMT_1 5 ACK TSN=04
1241.590 RCV_1 5 ACK TSN=04
1241.805 RTS_1 OFF
1241.805 DTR_1 OFF
1241.910 CTS_1 OFF
1242.010 DCD_1 OFF
1242.010 DSR_1 OFF
Figure 4–14: Sample of Brief Format slc_trac Trace Data Output