3.0 Battery Warnings
3.1 RF Lock
Warning level 1 for main battery
If the main battery of the lock goes empty, eight short signal tones, coming quickly
one after another, sound after you operate the transponder and before the cylinder
unlocks. You must replace both batteries now.
Warning level 2 for backup battery (SW Version 10.0 & SW Version 10.1)
In addition to the main battery warning, an additional eight short signal tones, coming
quickly one after another, now sound for the backup battery warning. The RF Lock
does not unlock until after the signals. From now on, the backup battery is active. You
must replace both batteries as soon as possible.
Warning level 2 for backup battery (SW Version 10.2 and later)
Now the signal tones of the backup battery warning sound for only approximately 30
seconds (without the main battery warning). The RF Lock does not couple until after
the signals. From now on, the backup battery is active. You must replace both
batteries as soon as possible.
Warning level 3 (SW Version 10.2 and later)
If you continue to ignore this backup battery warning, either the door can be used 50
more times or the RF Lock switches off after 4-5 weeks if there is no further
operation. In both cases, the lock switches into the so-called storage mode. After this,