User Manual

SV1C Cylindrical RF Lock
Page 4
An incorrectly installed RF Lock may block the access through a door. SimonsVoss
Inc. is not liable for the consequences of incorrect installation, such as blocked
access to injured or endangered persons, property damage or other damages.
If you will be storing the RF Lock for more than one week, remove the backup battery.
1.0 Operation
1.1 General Information
The SV1 Digital RF Lock is an ANSI Grade 1 lock and can easily be installed in any
door prepared according to the ANSI/BHMA A156.2-1996 standard. In comparison to
standard mechanical locks, this RF lock is just as easy to install, provides greater
security, is more flexible and costs less to operate..
Inner handle
Outer handle
1.2 Opening and Locking From Outside
When locked, the outer lever turns freely, not engaging the latch. It is not possible to
open the door from the outside. Hold the transponder at a distance of approximately 4
to 16 inches (10 to 40 cm) from the RF lock and briefly press the transponder button
once. If this is an authorized transponder, a double signal tone sounds and the lock
engages the latch. Now turn the outer lever. You have approximately three seconds
for this process. You can use the software to increase the unlock time if needed. The
longer the unlock time, the shorter the service life of the battery. After the specified
unlock time has expired, a single signal tone sounds and the outer lever turns freely
again.
If this transponder is not authorized at this time because of the time zone plan, a
single signal tone sounds, but the RF lock does not engage or unlock and you cannot
open the door.