5.5 Troubleshooting
1. Check door.
2. Check hinges. They should not be loose or have excessive wear on knuckles.
3. Latch will not deadlock. Either strike is out of line or gap between door and
jamb is too great. Realign strike or shim out towards flat area or latch.
4. Latch does not retract or extend properly. Latch tail and retractor not properly
positioned.
i. Remove lockset. Look through 2 1/8 hole and verify latch tail centered
between top and bottom of hole.
ii. Remove latch and insert lockset, look through latch hole and verify re-
tractor mouth centered in hole. Adjust outside rose plate if not.
iii. Re-bore holes if necessary to line up retractor and tail.
5.6 Programming the RF Lock
You must program the SimonsVoss SV1 Cylindrical RF Lock and accompanying
transponders in the lock plan software before you install them. Please refer to the
Software Operating Instructions for more detailed information.
The SimonsVoss RF Locks are delivered in storage mode, which means that no
communication is possible with the transponder. You can use software and the
programming device to remove the storage mode. Please refer to the Software
Operating Instructions for more detailed information.
5.7 Perform Function Test
1. With the door open, turn the inner lever. The lever must move easily.
2. Close the door and repeat the process. If the latch or lock is stiff, you probably
need to align the door or correct the strike plate.
3. Then perform the same test on the outer lever. To do this, operate an
authorized transponder near the lock.