User manual
MANUAL LSM MOBILE
Version: Juli 2010 V1.0
Page 38
the number with a 0 (zero). In the Password entry field, enter 0x0 (zero, small x, zero)
as the password. Click on OK.
• These values are the factory settings when a digital locking component is
supplied.
Click on OK to confirm the warning message that follows, asking you to confirm if you
want to apply this change. You can then program a new lock with the same
designation.
Note:
components should be reset and reprogrammed in LSM directly at the
workstation as a matter of principle, such that all data for the components and
their status is available in the database.
5.5. PERFORMING EMERGENCY OPENING OF A LOCK
If you need to perform an emergency opening using a programming device and the
Pocket PC, select the corresponding lock in your locking plan and highlight the
Emergency opening task. Click on the Run button and answer the security question
asking whether you want to perform this task with Yes.
Enter the emergency opening password and click on the Start button. The lock is now
opened.
• When using LSM as from version 2.2, you have to enter a specified emergency
opening password in LSM.
• You can also perform an emergency opening on locks that are not included in the
locking plan exported to the Pocket PC. To do this, the locking system password
programmed into the lock must be entered.